Corn Silage Mycotoxin Results - Dairyland
> 10 PPB
< 10 PPB
> 10 PPB
< 10 PPB
0.7  (TPR)
0.3  (FNR)
0.3  (FPR)
0.7  (TNR)
Above confusion matrix summarizes the performance of T2 HT2 test on ground corn. It includes four entries: true positive rate (TPR), false negative rate (FNR), false positive rate (FPR), and true negative rate (TNR).
Sensitivity
Specificity
Accuracy
0.7
0.7
70 %
ID
Lab Value (PPB)
Lab Class
Galaxy Class
Corn Type
ID
Lab Value (PPB)
Lab Class
Galaxy Class
Corn Type
The validation results for ground corn from Dairyland on T2 HT2 are shown above.  The comparison of Lab Values and Galaxy is shown. Lab values are the PPB reference values measured using HPLC. The  threshold for T2 HT2 is 10 PPB. The Galaxy Class is the output from the ImagoAI's rapid test.
> 1 PPM
< 1 PPM
> 1 PPM
< 1 PPM
0.8  (TPR)
0.2  (FNR)
0.75 (FPR)
0.25  (TNR)
Above confusion matrix summarizes the performance of Vomitoxin test on ground corn. It includes four entries: true positive rate (TPR), false negative rate (FNR), false positive rate (FPR), and true negative rate (TNR).
Sensitivity
Specificity
Accuracy
0.8
0.3
60 %
ID
Lab Value (PPM)
Lab Class
Galaxy Class
Corn Type
ID
Lab Value (PPB)
Lab Class
Galaxy Class
Corn Type
The validation results for ground corn from Dairyland on Vomitoxin are shown above.  The comparison of Lab Values and Galaxy is shown. Lab values are the PPM reference values measured using HPLC. The threshold for Vomitoxin is 1 PPM. The Galaxy Class is the output from the ImagoAI's rapid test.
> 100 PPB
< 100 PPB
> 100 PPB
< 100 PPB
1.0  (TPR)
0.0  (FNR)
0.33  (FPR)
0.7  (TNR)
Above confusion matrix summarizes the performance of Zearalenone test on ground corn. It includes four entries: true positive rate (TPR), false negative rate (FNR), false positive rate (FPR), and true negative rate (TNR).
Sensitivity
Specificity
Accuracy
1.0
0.7
89 %
ID
Lab Value (PPB)
Lab Class
Galaxy Class
Corn Type
ID
Lab Value (PPB)
Lab Class
Galaxy Class
Corn Type
The validation results for ground corn from Dairyland on Zearalenone are shown above.  The comparison of Lab Values and Galaxy is shown. Lab values are the PPB reference values measured using HPLC. The threshold for Zearalenone is 100 PPB. The Galaxy Class is the output from the ImagoAI's rapid test.
> 0.5 PPM
< 0.5 PPM
> 0.5 PPM
< 0.5 PPM
1.0  (TPR)
0.0  (FNR)
0.4  (FPR)
0.6  (TNR)
Above confusion matrix summarizes the performance of Fumonisin test on ground corn. It includes four entries: true positive rate (TPR), false negative rate (FNR), false positive rate (FPR), and true negative rate (TNR).
Sensitivity
Specificity
Accuracy
1.0
0.6
70 %
ID
Lab Value (PPM)
Lab Class
Galaxy Class
Corn Type
ID
Lab Value (PPB)
Lab Class
Galaxy Class
Corn Type
The validation results for ground corn from Dairyland on Fumonisin are shown above.  The comparison of Lab Values and Galaxy is shown. Lab values are the PPM reference values measured using HPLC. The threshold for Fumonisin is 0.5 PPM. The Galaxy Class is the output from the ImagoAI's rapid test.